UPS FSP CHAMP CH-1103TS 3000VA ONLINE T2700W (PPF24A1800)

599.000AMD
3000VA (2700W), Type: Online; F / F: Tower (421x190x318, 27.6kg); Entrance: C20; Output: 4xSchuko; Autonomy: 5 / 11min; Battery: 76VDC (6x 12V 9Ah); Protections: short circuit, overload, full battery discharge (PPF24A1800)

UPS Mercury Elite 3000 Smart

149.000AMD
  • Microprocessor Controlled - Guarantees High Reliability
  • Equipped With Boost and Buck AVR
  • Green Power Function for Energy Saving
  • DC Start Function
  • AC Overload Protection
  • Low Battery Voltage Indication
  • Full Protection: Discharge, Overcharge and Overload Protection
  • Load Level % Indication
  • Wide Input Voltage Range (140~300VAC)
  • Light Weight - Compact Design
  • LCD Display

APC Back-UPS 950VA, 230V, AVR, IEC Sockets

79.000AMD
Output power capacity
480Watts / 950VA
Max Configurable Power (Watts)
480Watts / 950VA
Nominal Output Voltage
230V
Output Frequency (sync to mains)
50/60 Hz +/-1 Hz
Output Frequency (not synced)
50/60 Hz +/-1 Hz
Topology
Line Interactive
Waveform type
Stepped approximation to a sinewave
Output Connections
(1) IEC Jumpers (Battery Backup)
(6) IEC 320 C13 (Battery Backup)
Transfer Time
8ms typical : 10 ms maximum

Mercury ELITE 1000 PRO UPS

39.000AMD
Input Voltage 220VAC
Input Frequency 50Hz
Input Phase Single Phase
Input Socket with FUSE
Cold Start (0~100% load) Press the ON / OFF Switch
Input Range (220V) 140V~285V
Normal Frequency 50Hz
Rating Output (VA) 1000VA
Rating Output (W) 600W
Waveform Battery Mode (Simulated Sine Wave) AC Mode (Sine Wave)
Power Factor 0.6
Rating Voltage 220V
Output Range 220VAC +17~22% (No Load Connected)
Rear Output Socket 3x IEC - Battery Backup
Transfer Time Typical 8ms (max 15ms)
Short Circuit Protection Line Mode FUSE & Software Protection 100%~120% (gives alarm & shut down in 3min) 120%~130% (beeps alarm & shut down in 30s) >130% (shut down immediately)
Battery Mode Software Protection controlled by CPU 100%~110% (gives alarm & shut down in 10s) >110% (shut down immediately)
Battery & Runtime Rating 12V / 9AH x1
Battery & Runtime Backup Time Typical 8mins~20mins
Battery & Runtime Change Current 1.5A (max)
Battery & Runtime Over Charge >14.8V ±0.5 (Stop Charging)
Battery & Runtime Protection <13.5V ±0.5 (Recharge)
Weight (kg) 7.5
Dimension (mm) 370 x 145 x 230
Master Carton (mm) 393 x 310 x 267 (2pcs)
Output Rating Frequency 50Hz
Output Line Mode Synchronize with the Utility
Output Battery Mode 50Hz ±1Hz

Mercury Elite 2000 Pro UPS

79.000AMD
Rating input voltage 2000 VA / 1200 W
Rating input frequency 60/50Hz (auto sensing)
Input phase Single phase
Input socket With Fuse
Cold Start (0 to 100% load) Press the ON/OFF Switch
Input Range (220V) 140-300
Rating output(VA) 2000
Rating output (W) 1200
Power factor 0.6
Rating output voltage (V) 220
Waveform Battery mode (simulated sine wave), AC mode(sine wave)
AC Voltage Regulation ±10% (Battery mode)
Rear output socket 4 x Universal - Battery backup
Waveform Simulated Sine Wave (Battery mode)
Line Mode Synchronize with the utility
Rating frequency 60Hz or 50 Hz ± 1 Hz
Battery Mode Yellow flashing
Short circuit protection Line Mode Fuse & Firmware protection
Short circuit protection Battery Mode Firmware Protection
Overload protection Line Mode 110%±5%; Go to fault mode Line Mode after 5 minutes, 120%±5%; Go to fault mode immediately.
Overload protection Battery Mode 110%±5%; Shutdown after 5 seconds, 120%±5%, Shutdown immediately
Indicators AC mode Green Lighting
Indicators Battery Mode Yellow Flashing
Indicators Fault Red Lighting
Alarm Battery Mode Sounding every 10 Seconds
Alarm Low Battery Sounding every Second
Alarm Overload Sounding every 0.5 second
Alarm Fault Continuously sounding
Full Protection Overload, discharge, and Overcharge protection
Transfer Time Typical 2-6ms, 10ms max.
Transfer Time Typical 2-6ms, 10ms max.
Communication Interface Optional RS232/RJ11
Battery and runtime Rating 2 X 12V/9AH
Recharge time - Typical 6-8 hours recover to 90% capacity
Charge current About 1A at normal mode.
Dimension, W X H X D (cm) 22.5 X 12.5 X 39
Net Weight (kgs) 12.7KGS
Humidity 0-90 % RH @ 0- 40°C (non-condensing)
Noise Level Less than 45dB
Compatible with OS Supports Windows® 2000/2003/XP/Vista/2008/7
Communication interface Elite 2000pro (N/A), Elite 2000ipro (USB/RJ11)

Mercury ELITE 650 PRO Line UPS

23.000AMD
Input voltage 220VAC
Input frequency 50Hz
Input phase Single phase
Input socket With Fuse
Cold Start (0 to 100% load) Press the ON/OFF switch
Input range (220V) 140V-300V
Rating output (VA). 650VA
Rating output (W). 390W
Rating output (W). Battery mode(simulated sine wave), AC mode (sine wave)
Power factor 0.6
Rating voltage 220V
Output range 220Vac-7%+15% ( in battary mode )
Rear Output Socket 2xUniversal - Battery backup
Transfer time TYPICAL 4-8 ms
Communication Interface NIL
Rating frequency 50Hz
Output Frequency Line-mode Synchronize with the Utility
Battery mode 50 Hz±1Hz
Output Frequency Line Mode Synchronize with the utility
Short Circuit Protection Line Mode FUSE & firmware protection
Battery Mode Software protection controlled by firmware
Overload Protection Line Mode 110%+-5% (Go to fault mode after 5 minutes), 120%+-5% (Go to fault mode immediately)
Battery Mode 110%+-5% (Shutdown after 5 minutes) 120%+-5% (Shut down immediately)
Rating frequency 12V/8.2AH x 1
Backup Tim - Typical 10mins to 18mins (depending on load)
Charge Current About 1A at normal mode
Over Charge Protection >14.5V +/- 0.2V stop charging <13.5V +/- 0.5V Recharge
Weight 5.6kg +/- 0.3Kg
Dimension 390x 145 x 220 (mm)
Master Carton 45.5 x 40 x 23.5 (cm) (4pcs)

Mercury ELITE 850 PRO Line UPS

29.000AMD
Input .
Input Voltage 220VAC
Input Frequency 50Hz
Input Phase Single phase
PowerCord Built-in Cable with Fuse
Input Voltage Range 140~300VAC
Output .
Rating Output 850VA
Wave Form Battery Mode (Simulated Sine Wave) AC Mode (Synchronize with Input)
Rating Voltage 220V
Output Range 220VAC-11% to +17% (Battery Mode)
Rear Output Socket 2xUniversal-Battery Backup
Transfer Time Typical 4-8ms
Communication Interface Nil
Output Frequency .
Rating Frequency 50Hz
Line Mode Synchronize with the Utility
Battery Mode 50Hz±1Hz
Short Circuit Protection .
Line Mode Fuse & Firmware Protection
Battery Mode Firmware Protection
Overload Protection .
Line Mode 110%±5% (go to fault mode after 5 minutes) 120%±5% (go to fault mode immediately)
Battery Mode 85%±5% (Shut down after 5 seconds) 100%±5% (shut down immediately)
Battery and Runtime .
Rating 1x12V/9AH
Backup Time - Typical 15mins~25mins (Depending On Load)
Charging Current About 1A at Normal Mode
OverCharge Protection 14.5V±0.2V(Stop Charging) <13.5V±0.5V(Recharge)
Packaging .
Dimension(mm) 350x142x213
Master Carton(mm) 365x304x446
Packsize per Master Carton(mm) 2

Mercury Elite1500 Pro UPS

65.000AMD
Input .
Input Voltage 220VAC
Input Frequency 50Hz
Input Phase Single Phase
PowerCord Built-in Cable with Fuse
Input Voltage Range(May vary as per Country requirement) 140~300VAC
Output .
Rating Output 1500VA
Wave Form Battery Mode (Simulated sine Wave) AC Mode (Synchronize with Input)
Rating Voltage 220V
Output Range 220VAC - 11% to + 17% (Battery Mode)
Rear Output Socket 4x Universal - Battery Backup
Transfer Time Typical 4-8ms
Communication Interface Nil
Output Frequency .
Rating Frequency 50Hz
Line Mode Synchronize with the Utility
Battery Mode 50Hz±1Hz
Short Circuit Protection .
Line Mode FUSE & Firmware Protection
Battery Mode Firmware Protection
Overload Protection .
Line Mode 110%±5% (go to fault mode after 5 minutes) 120%±5% (go to fault mode immediately)
Battery Mode 85%±5% (shut down after 5 seconds) 100%±5% (shut down immediately)
Battery and Runtime .
Rating 2x12V/8.2AH
Backup Time - Typical 30mins~40mins (Depending On Load)
Charging Current About 1A at Normal Mode
OverCharge Protection 29V±0.2V(Stop Charging) <27V ±0.5V(Recharge)
Packaging .
Dimension(mm) 388x203x260
Master Carton(mm) 425x403x280
Packsize per Master Carton(mm) 2